Central Minnesota Appliance RepairCMN Appliance
ANETS · TWIN CITIES

Anets Fryer Repair in Minneapolis & St. Paul

Anets fryer repair in Minneapolis, St. Paul and the Twin Cities, 7am to 9pm daily. Equipment covered: Gold Series (AGG, 14GS); Silver and Silver Plus gas fryers; Platinum gas (AGP); Platinum electric (AEP); Filter drawers.

Who does Anets fryer repair in the Twin Cities?

Central Minnesota Appliance Repair repairs Anets Gold, Silver and Platinum gas and electric fryers, open-pot 14GS GoldenFry fryers and fryer filter drawers across Minneapolis, St. Paul and the Twin Cities, 7am–9pm every day. We are an independent shop, not an authorized service agency for Anets. The diagnostic is $199–$299, waived when you approve the repair.

Book an Anets fryer diagnostic online or call (651) 364-7466.

Last updated

About Anets

Anets, based in New Hampshire, makes gas and electric fryers, pasta cookers and fryer filtration. Its website lists Platinum, Gold, Silver Plus and Silver series fryers and says it is part of the Middleby Corporation. An older Anets manual calls the 14G, 14GS and MX-14EG family "The Anets Golden Line," and the SLG series is marked discontinued on the Anets documentation page.

We confirm the model, serial number and gas or electrical rating from the data plate, work from the Anets manual for that model and tell you what the repair needs before work starts. For other fryer makers see commercial fryer repair, or Pitco fryer repair for the sister brand listed on the Anets site.

Anets equipment we service

Anets fryer lines we service and their common failure patterns
Series / linePositioningCommon failures
Gold Series and GoldenFryAGG14, AGG14R, AGG14T and AGG18 tube-fired gas fryers, plus the open-pot 14GSStanding pilot, thermocouple, gas control valve, millivolt thermostat, high-limit
Silver and Silver Plus35AS, 40AS, 45AS and 70AS, plus 40AV and 70AV gas fryersPilot, thermostat, high-limit, gas valve, drain valve
Platinum gas (AGP)AGP55, AGP55T, AGP60, AGP60W and AGP75 with matchless ignition and drain valve interlockIgnition, drain valve interlock, solid-state thermostat, high-limit, burner
Platinum electric (AEP)AEP14, 14R, 14X, 14T, 14TX, 18 and 18R electric fryersHi-limit, heating contactors, temperature probe, controller, drain interlock
Filter drawersFilter drawer, Filtermate and Filtronic II filtrationPump, return valve, motor overload, filter media, hoses

Common Anets failure patterns

  • Pilot goes out repeatedly: the 14G manual lists low gas supply pressure, a loose thermocouple or high-limit connection, a draft, or a high-limit fault that has shut off the gas.
  • Main burners will not light or will not shut off: the 14G manual points to the gas control valve or the thermostat.
  • Oil will not reach frying temperature: the 14G manual lists low supply or manifold pressure, or a thermostat needing calibration.
  • AEP heat light on but elements not heating: the AEP manual says the hi-limit may have tripped if the oil is hot.
  • AEP display stuck on DRAINING or TURN OFF: a blue drain valve not fully closed or a loose sensor switch.
  • AEP filter pump silent with the red return valve open: tripped filter breaker or motor overload.

Anets parts we replace

Common Anets parts include thermocouples, gas control valves and thermostats. Parts are OEM.

  • Thermocouples
  • Gas control valves
  • Thermostats
  • High-limit thermostats
  • Piezo igniters
  • Filter envelopes and paper
  • Heating contactors
  • Temperature probes

Anets commercial repair FAQ

Which Anets fryers do you repair?
We repair Anets Gold Series AGG and 14GS fryers, Silver and Silver Plus gas fryers, Platinum AGP gas and AEP electric fryers, and the filter drawers that go with them. Send the plate photo and a description of the fault so we can match the manual to the model.
Where is the data plate on an Anets fryer?
The Anets AEP electric manual puts the data plate on the inside of the appliance door and says to match the voltage and phase to it. The older 14G manual calls it the spec plate and ties the gas type to it. Photograph it before you call.
Why does my Anets gas fryer's pilot keep going out?
The 14G and 14GS manual lists low gas supply pressure, a loose thermocouple or high-limit connection, a draft around the pilot, and a high-limit fault that has shut off the gas. It also says all repairs and part replacement go to a qualified service agency, so we test the circuit and replace the failed part.
My Anets electric fryer's heat light is on but the elements do not heat. What do I check?
The AEP manual gives one cause for this: if the oil is hot, the hi-limit may have tripped. It says to let the oil cool before the limit is reset and the computer is turned off and on again. If nothing shows on the display at all, it lists the building breaker and a blown fryer fuse, which goes to an authorized technician.
Are you an authorized Anets service agency, and what about warranty?
No. We are an independent company and not an authorized service agency for Anets. The Anets manuals send warranty claims to an Anets Authorized Service and Parts distributor and say repairs by unauthorized personnel void the warranty, so a fryer under warranty should go there first. Our repairs carry a 1-year parts-and-labor warranty.
How much does Anets fryer repair cost?
The commercial diagnostic is $199–$299 depending on the equipment and is waived when you approve the repair. For a fryer thermopile, pilot or high-limit reset job, our range is $285–$585 parts and labor. Repairs carry a 1-year parts-and-labor warranty.

Which Anets fryers are in Twin Cities kitchens?

Anets sells its current fryers in series. The Anets site lists Platinum gas and electric fryers, Gold Series fryers, Silver Plus and Silver, and describes the Gold Series as higher production fryers with filtration. Anets documents also cover the open-pot 14GS, which still appears in the GoldenFry brochure, and an older manual for the 14G, 14GS and MX-14EG that calls them "The Anets Golden Line." The SLG series is marked discontinued on the Anets documentation page.

The first job on any Anets call is to place the fryer in the right series, because the controls differ so much. The data plate settles which one you have. The AEP manual puts it on the inside of the door.

Anets lines and one documented fact about each

Figures are from Anets spec sheets, brochures and manuals. Options vary, so check your own plate.

LineModelsWhat the Anets document says
Gold Series (tube-fired gas)AGG14, AGG14R, AGG14T, AGG18Millivolt thermostat with a high temperature limit switch that shuts off all gas flow above the upper limit.
GoldenFry open pot14GSThe brochure describes a 14 x 14 inch stainless tank, a 3.25 to 4.5 inch cook depth and a patented cross fire burner.
Older Golden Line manual14G, 14GS, 14GU, 14GSU, MX-14EGRated 111,000 BTU. The manual says the 14GS and MX-14EG need no external electric power source.
Silver Economy35AS, 40AS, 45AS, 70ASAll four list a millivolt control. The 35AS is 90,000 BTU with three tubes and the 70AS is 150,000 BTU with five.
Silver Plus40AV, 70AVRated 70,000 and 95,000 BTU/hr.
Platinum gasAGP55, AGP55T, AGP60, AGP60W, AGP75The spec sheet lists a self-cleaning burner with a daily 30 second cleaning cycle, down draft protection and a DVI drain valve interlock.
Platinum electricAEP14, 14R, 14X, 14T, 14TX, 18, 18RFixed heating elements, mercury-free heating contactors and a drain valve interlock. Ratings run from 14 to 22 kW.

Source: Anets documentation

What Anets manuals say the operator can do

Keep the flue and hood clear

The 14G manual says never to run the fryer with a blocked flue or the hood off, and to check the flue behind the backsplash once a month so exhaust gases flow freely toward the hood.

Keep the oil at the right level

The AEP manual warns of a fire danger if the oil level falls below the minimum line, and says the crumb catch and filter pan contents go into a fireproof container at the end of each day.

Check temperature against a thermometer

The AEP manual's monthly check puts a thermometer in the oil within 1 inch of the probe tip and compares it to the setpoint. If they are more than 5 degrees F apart it says to measure again before contacting an authorized service company.

Built-in filtration

The 14G manual says not to pump cleaning solution through a built-in filter system. The AEP manual limits the filter pump to three consecutive cycles, then at least a 20 minute break.

Melt solid shortening first

On the 14G family, the manual says solid shortening must be melted before it goes into the fryer, and that damage from melting it in the kettle is not covered by the warranty.

What the manuals reserve for a qualified technician

Repairs and part replacement

The 14G troubleshooting guide opens with "All service (repairs or part replacement) must be performed by a qualified Service Agency." The AEP manual keeps its annual inspection for a qualified technician.

Safety limits

For a pilot that will not stay lit, the 14G manual includes a test of the high-limit thermostat and then states not to return the fryer to normal operation with the high-limit bypassed or disconnected.

Gas supply

For low supply pressure, the 14G manual says to contact the local gas supplier.

Messages and symptoms the Anets manuals name

Symptom or messageCauses the manual listsWhat the manual says to do
AEP display shows DRAINING or TURN OFF with the drain valve closedBlue drain valve not fully closed, or a loose sensor switchPress the valve fully closed. Tighten loose switch screws if possible, otherwise call a service agency
AEP heat light on, elements do not heatHi-limit may be tripped if the oil is hotLet the oil cool before the hi-limit is reset
AEP display blankBuilding circuit breaker off, or a blown fryer fuseCheck the building breaker. A blown fuse goes to an authorized service technician
AEP red return valve open, no pump soundValve not fully open, filter breaker, motor thermal overload or a loose sensor switchPull the red valve handle fully open, reset the filter breaker behind the left fryer door or press the red reset button on the filter motor. A loose sensor switch that cannot be tightened goes to a service agency.

Source: Anets AEP Series manual 150-000010 Rev C

More questions about Anets fryers

How do I tell a 14GS from an AGG14 GoldenFry?

The Anets brochure calls the 14GS an open-pot fryer with a cross fire burner and the AGG fryers tube-fired, with the AGG14 as the base model of the GoldenFry series.

Does an Anets gas fryer need electricity?

The 14G manual says the 14GS and MX-14EG need no external electric power source. The Platinum AGP spec sheet lists matchless ignition that lights the pilot when the power is turned on.

Central Minnesota Appliance Repair · Independent appliance repair since 2009 · Open daily 7am to 9pm · (651) 364-7466 · 222 E Hennepin Ave, Minneapolis