Central Minnesota Appliance RepairCMN Appliance
HEATCRAFT · BOHN · LARKIN

Heatcraft, Bohn & Larkin Walk-In Repair in Minneapolis & St. Paul

Heatcraft walk-in repair in Minneapolis, St. Paul and the Twin Cities, 7am to 9pm daily. Equipment covered: Walk-in unit coolers, Condensing units, PRO3 top-mount packaged systems.

Who does Heatcraft walk-in repair in the Twin Cities?

Central Minnesota Appliance Repair repairs Heatcraft, Bohn and Larkin walk-in unit coolers, condensing units and PRO3 packaged systems in Minneapolis, St. Paul and the Twin Cities, 7am–9pm every day. We are an independent company, not part of the manufacturer's service network. The diagnostic is $199–$299, waived when you approve the repair.

Book a Heatcraft walk-in diagnostic online or call (651) 364-7466.

Last updated

About Heatcraft

Heatcraft Refrigeration Products is part of Lennox International. Its own site lists Bohn, Larkin, Climate Control and Chandler among its brands, and the low profile walk-in unit cooler listings we compared there show the same specifications under Bohn (model prefix BEL) and Larkin (prefix LEL).

We read the tag on the unit cooler and on the condensing unit or packaged system, then work from the manual for that equipment. For the insulated box, doors and gaskets see walk-in cooler repair.

Read next: Why a walk-in evaporator ices up.

Heatcraft equipment we service

Heatcraft walk-in lines we service and their common failure patterns
Series / linePositioningCommon failures
Walk-in unit coolersLow profile, low velocity center mount, center mount and medium profile evaporatorsFan motors, defrost heaters and termination, drain pan and drain line heaters, ice on fan guards
Condensing unitsAir-cooled, remote compressor and water-cooled unitsDirty condenser coil, condenser fan, controls
PRO3 top-mount systemsUnit cooler and condensing unit in one package on the box, P1, P2 and P3 cabinetsController probe alarms, defrost, evaporator and condenser fans, leak sensor alarms on equipped models

Common Heatcraft failure patterns

  • Evaporator fans will not run: open switch, blown fuse, failed motor or a failed defrost control.
  • Ice on the ceiling, fan guards or blades: defrost too long, fan delay not working, or a failed defrost control.
  • Coil does not clear during defrost: coil staying below freezing, too few or too short defrost cycles, or a failed timer.
  • Ice in the drain pan: failed heater, drain line plugged, unit not pitched, or a dead drain line heater.
  • Uneven coil frosting: defective heater, unit too close to a door, or defrost termination set too low.

Heatcraft parts we replace

Common Heatcraft parts include evaporator fan motors, defrost heaters and drain pan heaters. Parts are OEM.

  • Evaporator fan motors
  • Defrost heaters
  • Drain pan heaters
  • Defrost termination controls
  • Electronic thermostats

Heatcraft commercial repair FAQ

Do you repair Bohn and Larkin walk-in unit coolers?
Yes. Heatcraft's own site lists Bohn and Larkin among its brands, and its low profile unit cooler listings carry both names. We repair Heatcraft walk-in unit coolers, condensing units and PRO3 packaged systems in the Twin Cities. Send the model and serial tag and what the box is doing.
Are you an authorized service agency for Bohn or Larkin?
No. We are an independent company, not part of the manufacturer's service network. Equipment under warranty should go to that network first. Heatcraft's HFC unit cooler manual states one year from installation or 18 months from shipment, whichever comes first, and its PRO3 manuals state two years or 30 months, whichever comes first.
Where is the data plate on a Heatcraft unit cooler?
Heatcraft's HFC unit cooler manual refers to a serial data tag on the unit that is marked with its electrical characteristics, and puts the wiring diagram inside the electrical panel door. The manual gives no single spot for the tag, so photograph it and send it before anyone opens a panel.
Why are my unit cooler fans not running?
Heatcraft's chart lists an open main switch, blown fuses, a failed motor, a bad defrost timer or thermostat, or a unit in its defrost cycle. For a unit in defrost the manual's advice is to wait for the cycle to finish. Everything electrical is for a technician.
What does a P1 or P2 message on a PRO3 controller mean?
The PRO3 manual calls P1 to P4 probe alarms. They start seconds after a probe fault and stop on their own once the probe reads normally. Write down which message shows, since the manual says to check connections before replacing a probe.
How much does Heatcraft, Bohn or Larkin repair cost?
Commercial diagnostic is $199–$299 depending on the equipment; it's waived when you approve the repair, and you get a written quote before any repair work. Repairs carry a 1-year parts-and-labor warranty.

Who Heatcraft is and what Bohn and Larkin mean on a walk-in

Heatcraft Refrigeration Products is part of Lennox International (its site calls it a business segment) and is based in Stone Mountain, Georgia. Its site says it makes unit coolers, condensers, compressorized racks, condensing units and refrigeration systems under brands that include Bohn, Larkin, Climate Control, Chandler, intelliGen and InterLink. InterLink is the replacement parts line, not a kind of equipment.

On a walk-in that matters in one practical way. The unit cooler inside the box, the condensing unit outside it and a PRO3 package on top of it each have their own tag and their own manual. We read the tag first, then the manual for that exact model.

Heatcraft walk-in equipment and what its documents say

EquipmentWhat Heatcraft saysWhy it matters at the box
Low profile unit coolersHinged removable panels, motors that plug into a wiring harness, extended drain pan heaters, and air, electric or hot gas defrostThe model tag decides which defrost parts apply
Center mount and medium profileListed as separate walk-in lines beside low profile and low velocity center mountThe HFC unit cooler manual gives separate clearance figures for each style
Slim ContourModular fan cassettes with a service clip, described under Discontinued Unit CoolersOlder boxes may still carry them. Cassette removal in the manual is service work that starts with the power off
Condensing unitsAir-cooled, remote compressor and water-cooled familiesIn the condensing section of a PRO3, a dirty condenser coil and a stopped condenser fan are both on the manual's high discharge pressure list
PRO3 top mountUnit cooler and condensing unit in one package, in P1, P2 and P3 cabinetsIndoor and outdoor models have separate manuals. The indoor manual limits indoor units to ambient air of 50°F to 100°F, and outdoor P2 and P3 units can carry a weather hood

Model families are taken from Heatcraft's product pages and its H-IM-UC, H-IM-81E and H-IM-82D manuals.

Source: Heatcraft unit coolers

What Heatcraft's manuals say an operator can check

These come from Heatcraft's own documents. Most need no tool or open panel. Drain pan cleaning is for whoever maintains the box.

Product and door clearance

Heatcraft's HFC unit cooler manual says to leave space equal to the unit's height between the bottom of the unit and the product, and not to stack product in front of the fans. It also says never to locate evaporators over doors.

Where the ice is

The HFC unit cooler manual's troubleshooting chart separates ice on the ceiling, fan guards or blades, a coil that will not clear during defrost, ice in the drain pan and uneven frosting. Each has a different list of causes, so note which you see. Our evaporator icing guide covers the rest.

Drain pan

The manual asks that the pan be inspected for free drainage and cleaned with warm soapy water, with a warning that power must be disconnected first because the pan also covers moving parts. Ask whoever maintains the box to do it.

Controller messages

A PRO3 controller flashes an alarm message in turn with the temperature. Probe alarms P1 to P4 clear by themselves when the probe reads normally. Temperature alarms HA, LA, HA2 and LA2 clear when the temperature returns to normal. Write the message down for us.

What Heatcraft reserves for qualified service

Heatcraft's HFC unit cooler manual states that installation and maintenance are to be performed only by qualified personnel familiar with this type of equipment. The PRO3 manual adds that safety-related procedures such as breaking into the refrigerating circuit, opening sealed components and opening isolated enclosures are for competent persons only. It also warns against any means of speeding up defrost or cleaning other than those the manufacturer recommends.

On PRO3 models fitted with a refrigerant leak sensor, the manual says a detected leak turns the compressor off, puts the evaporator fan on low speed and, if the unit is in defrost, switches off the defrost heaters, and that a service technician must reset the detection controller. It says to verify the leak is fixed before resetting, and that field installation of a leak sensor is not allowed. Our technicians hold EPA Section 608 Universal certification, and we quote sealed-system work before it starts. We are an independent shop, so a unit still under Heatcraft warranty should go to the manufacturer's network first.

More questions about Heatcraft, Bohn and Larkin walk-ins

Are Climate Control and Chandler Heatcraft brands too?

Yes. Heatcraft's site and its unit cooler manual both name Climate Control and Chandler beside Bohn and Larkin. If your equipment carries one of those names, send the tag and we will confirm what it is before we quote.

Does a Bohn unit cooler differ from a Larkin one?

On the Heatcraft low profile listings we compared, capacity, airflow, fin spacing, refrigerant and defrost type match, and only the model prefix changes, BEL for Bohn and LEL for Larkin. The tag on your unit and its manual are what decide which parts apply.

What is a PRO3 system?

Heatcraft describes PRO3 as a package that combines a unit cooler and a condensing unit into one system. It comes in P1, P2 and P3 cabinets, and its manual covers a controller, defrost and, on some models, a refrigerant leak sensor.

Central Minnesota Appliance Repair · Independent appliance repair since 2009 · Open daily 7am to 9pm · (651) 364-7466 · 222 E Hennepin Ave, Minneapolis